CHEMICAL DOSING ACCESSORIES
Oil, Refining and Petrochemical
I.C.E. have strong experience with the metering of chemicals used in all phases of the production, processing, refining, transmission and distribution of oil and gas products.
Natural gas, LPG, LNG & Biogas
I.C.E. are Australian leaders in providing trusted equipment for the metering of corrosion inhibitors for instrument protection, methanol to prevent freezing, and odorant injection for public safety.
Offshore Industry
I.C.E. have the technical knowledge and product range for the metering of Oil and Gas corrosion inhibitors, emulsion breakers, oxygen scavengers, methanol injection and many others.

LINC Level Control
LINC manufactures level and flow switches for hazardous applications requiring corrosion resistance and explosion-proof ratings. Environmentally isolated design keeps operational fluids separate from control circuit.
Linc Level Switch Brochure
- Available with 316 stainless steel and polypropylene displacer option for various process pressures.
- NPT and externally caged process connections available.
- Standard cartridge switch is SPST with optional SPDT available.
- Flow switches also available.
LINC-282 Pneumatic Level Switch
These units are used as a level control or as a high or low level alarm. The pneumatic output can be used to operate valves, sound alarms or perform and other desired pneumatic function.
- Easy to repair: Repairs on-site in 20 minutes with the “quick-change” pneumatic cartridge
- Easy to field test: The manual override option enables mechanical and pneumatic unction testing while installed
- Output: Non-bleed; Snap-acting
- Working Pressure: 0-1,500 PSIG standard (available to 5,000 PSIG)
- Specific Gravity: 0.5 minimum
- Supply Pressure: 30, 60, 100 PSIG standard
- Output Pressure: 0-30, 0-60, 0-100 PSIG
- Materials: 316SS wetted and housing components
- Connections: 2″ NPT standard; available 3″ or larger
LINC-282SC Externally Caged Pneumatic Level Switch
These units are used as a level control or as a high or low level alarm. The pneumatic output can be used to operate valves, sound alarms or perform and other desired pneumatic function.
- Easy to repair: Repairs on-site in 20 minutes with the “quick-change” pneumatic cartridge
- Easy to field test: The manual override option enables mechanical and pneumatic function testing while installed
- Output: Non-bleed; Snap-acting
- Working Pressure: 0-1,500 PSIG standard (available to 5,000 PSIG)
- Specific Gravity: 0.5 minimum
- Supply Pressure: 30, 60, 100 PSIG standard
- Output Pressure: 0-30, 0-60, 0-100 PSIG
- Materials: 316SS wetted and housing components
- Connections: flanged and externally caged
Options: Manual override, annulus plug, displacers
L471 Electric Level Switch
Used as a high & low level control, the L471 can activate alarms, provide a switch input for control systems or perform a variety of desired electrical switch operations actuated by a liquid or liquid interface.
- Easy to repair: Repairs on-site in 20 minutes with the “quick-change” switch cartridge
- Easy to field test: The manual override option enables mechanical and electric function testing while installed
- Working Pressure: 0-1,500 PSIG standard (available to 5,000 PSIG)
- Switch Rating: SPST; 100VA AC; 100W DC; 3 amp in-rush capability, maximum of 250 volts, Hermetically sealed
- Materials: 316SS wetted and housing components (available in other austenitic metals and plastics)
- Connections: 1-1/2″ NPT standard; available 2″ or larger
- Electrical Connection: 1/2″ conduit
- CSA Certification: Listed as explosion-proof for Class I, Div. 1, Groups A, B, C, D; Class II, Div. 1, Groups E, F, G; and Class III, Div. 1
- Manual override & 10 Amp relay assembly
- Annulus plug & displacers
L471SC Externally Caged Electric Level Switch
Used as a high & low level control, the L471SC can activate alarms, provide a switch input for control systems or perform a variety of desired electrical switch operations actuated by a liquid or liquid interface.
- Easy to repair: Repairs on-site in 20 minutes with the “quick-change” switch cartridge
- Easy to field test: The manual override option enables mechanical and electric function testing while installed
- Working Pressure: 0-1,500 PSIG standard (available to 5,000 PSIG)
- Switch Rating: SPST; 100VA AC; 100W DC; 3 amp in-rush capability, maximum of 250 volts, Hermetically sealed
- Materials: 316SS wetted and housing components (available in other austenitic metals and plastics)
- Connections: 1-1/2″ NPT standard; available 2″ or larger
- Electrical Connection: 1/2″ conduit
- CSA Certification: Listed as explosion-proof for Class I, Div. 1, Groups A, B, C, D; Class II, Div. 1, Groups E, F, G; and Class III, Div. 1
Options: Manual override, 10 Amp relay assembly, annulus plug, displacers
LV471 Vertical Electric Level Switch
Used as a high & low level control, the LV471 can activate alarms, provide a switch input for control systems or perform a variety of desired electrical switch operations actuated by a liquid or liquid interface.
- Easy to repair: Repairs on-site in 20 minutes with the “quick-change” switch cartridge
- Working Pressure: 0-250 PSIG
- Specific Gravity: 0.7 minimum
- Switch Rating: SPST; 100VA AC; 100W DC; 3 amp in-rush capability, maximum of 250 volts, Hermetically sealed
- Materials: 316SS wetted parts
- Connections: 1-1/2″ NPT standard; available flanged
- Electrical Connection: 1/2″ conduit
- CSA Certification: Listed as explosion-proof for Class I, Div. 1, Groups A, B, C, D; Class II, Div. 1, Groups E, F, G; and Class III, Div. 1
Option: 10 Amp relay assembly
L 971 Horizontal Extended Body Electric Level Switch
Used as a high & low level control, the L971 can activate alarms, provide a switch input for control systems or perform a variety of desired electrical switch operations actuated by a liquid or liquid interface.
- Easy to repair: Repairs on-site in 20 minutes with the “quick-change” switch cartridge
- Working Pressure: 0-2,500 PSIG
- Specific Gravity: 0.6 minimum
- Switch Rating: SPST; 100VA AC; 100W DC; 3 amp in-rush capability, maximum of 250 volts, Hermetically sealed
- Materials: Displacer is polypropylene, all other wetted parts 316SS
- Connections: 1″ NPT standard; available in 1-1/2″ NPT or flanged
- Electrical Connection: 1/2″ conduit
- CSA Certification: Listed as explosion-proof for Class I, Div. 1, Groups A, B, C, D; Class II, Div. 1, Groups E, F, G; and Class III, Div. 1
- 10 Amp relay assembly
Level Measurement

Kenco Liquid Level Measurement
Manufacturer of a broad range of liquid level indicators, tank gauges, calibration cylinders and pump setting gauges, sight flow indicators and injection quills.
Draw Down Cylinders (Calibration Cylinders)
5700 Injection Rate Gauges
The 5700 Series Gauge provides a visual means for checking the contents of a bulk tank and a means for checking the injection rate of a chemical metering pump. This is achieved by conducting a one minute test.
Calibration Pots
Drum Gauges
Injection Quills
KENCO Chemical Injectors are designed to inject and properly atomize corrosive chemicals into the turbulent stream of a process system pipeline. The KENCO Chemical Injector will minimize the possibility of corrosive chemical build-up on the walls of the pipeline.
KENCO Chemical Injectors are recommended for use in pipelines with a flow-rate velocity of 40 feet per second (12.192 meters per second), or less.
Hoffman Controls
DPH-4 Controller
PPH-1 Controller
- The first operates by cycling on / off timers, this is known as normal.
- The second operates in a proportional manner, dosing towards the set point at a reduced rate. This avoids over dosing.
- The third is known as adaptive proportional capacity to ‘learn’ from the behaviour of the system and adjust it’s on and off by an algorithm programmed into the instrument.
PMV-1 ORP Controller
- The first operates by cycling on / off timers, this is known as normal.
- The second operates in a proportional manner, dosing towards the set point at a reduced rate. This avoids over dosing.
- The third is known as adaptive proportional capacity to ‘learn’ from the behaviour of the system and adjust it’s on and off by an algorithm programmed into the instrument.
DPH-64 Controller
CTH-2 Cooling Tower Controller
SMH-2 Simulator
Etatron Peristaltic Pumps